Oscilloscope Probes
Home > Mall > Oscilloscope Probes
  • ETA5520A  Current probe
    • Bandwidth

      DC-30MHz

    • Current

      DC/AC peak 20A

    • Rise time

      ≤12ns

    • Range sensitivity

      100mV/A

    • Typical DC Accuracy

      士2%rdg

    • Maximum operating voltage

      CATI 400V

    • Zero adjustment mode

      Automatic

    • Power supply modenction

      5V/2A power supply

    • Jaw diameter

      Φ4.5mm

    • Interface Type

      BNC

    • Weight

      200g

    • Overall dimension

      230mmx45.5mmx24.5mm

    • Maximum pulse current

      25A(TP≤10uS)

    • Noise

      ≤1mVrms

    • Linearity

      ±1%

    • Delay time

      20ns

    • Cable length

      130cm

    $634.00
  • ETA5540B  Current probe
    • Bandwidth

      DC-50MHz

    • Current

      DC/AC peak 40A

    • Rise time

      ≤7ns

    • Range sensitivity

      50mV/A

    • Typical DC Accuracy

      士2%rdg

    • Maximum operating voltage

      CATI 400V

    • Zero adjustment mode

      Automatic

    • Power supply modenction

      5V/2A power supply

    • Jaw diameter

      Φ4.5mm

    • Interface Type

      BNC

    • Weight

      200g

    • Overall dimension

      230mmx45.5mmx24.5mm

    • Maximum pulse current

      50A(TP≤10uS)

    • Noise

      ≤1mVrms

    • Linearity

      ±1%

    • Delay time

      20ns

    • Cable length

      130cm

    $1,063.00
  • ETA5540A  Current probe
    • Bandwidth

      DC-30MHz

    • Current

      DC/AC peak 40A

    • Rise time

      ≤12ns

    • Range sensitivity

      50mV/A

    • Typical DC Accuracy

      士2%rdg

    • Maximum operating voltage

      CATI 400V

    • Zero adjustment mode

      Automatic

    • Power supply modenction

      5V/2A power supply

    • Jaw diameter

      Φ4.5mm

    • Interface Type

      BNC

    • Weight

      200g

    • Overall dimension

      230mmx45.5mmx24.5mm

    • Maximum pulse current

      50A(TP≤10uS)

    • Noise

      ≤1mVrms

    • Linearity

      ±1%

    • Delay time

      20ns

    • Cable length

      130cm

    $849.00
  • ETA56150A  Current probe
    • Bandwidth

      DC-20MHz

    • Current

      DC/AC RMS 150A

    • Rise time

      ≤18ns

    • Range sensitivity

      0.1V/A 0.01V/A

    • Typical DC Accuracy

      士1%+10mA@0.1V/A 士1%+100mA@0.01V/A

    • Maximum operating voltage

      600V CATII 300V CATIII

    • Zero adjustment mode

      Automatic

    • Power supply modenction

      12V/2A power supply

    • Jaw diameter

      Φ19mm

    • Interface Type

      BNC

    • Weight

      523g

    • Overall dimension

      Control box: 109mm x 24.2mm x 57.8mm //Current clamp: 170mm x 30mm x 65mm

    • Delay time

      Probe host 31ns //BNC 5ns (line length 1 m)

    • Cable length

      Control box to BNC connector cable length: 0.9m// Cable length from control box to current clamp: 1.4m

    $2,764.00
  • ETA5303A  Current probe
    • Bandwidth

      DC-10KHz

    • Current

      DC/AC peak 600A

    • Rise time

      ≤35us

    • Range sensitivity

      1mV/A、10mV/A

    • Typical DC Accuracy

      +1.5%+5mV

    • Maximum operating voltage

      CATI600V、CATI 600V、CATII 300V

    • Typical battery type and life

      9V NEDA1604A,IEC 6LR61 40 hoursminimum (leach)

    • Zero adjustment mode

      Automatic

    • Overload indication

      Current out of range, red light flashing

    • Jaw diameter

      Φ30 mm /Φ24 mm x2

    • Weight

      440g

    • Overall dimension

      224x97x44mm

    $999.00
  • ETA56300A  Current probe
    • Bandwidth

      DC-8MHz

    • Current

      DC/AC RMS 300A

    • Rise time

      ≤44ns

    • Range sensitivity

      0.1V/A 0.01V/A

    • Typical DC Accuracy

      士1%+10mA@0.1V/A 士1%+100mA@0.01V/A

    • Maximum operating voltage

      600V CATII 300V CATIII

    • Zero adjustment mode

      Automatic

    • Power supply modenction

      12V/2A power supply

    • Jaw diameter

      Φ19mm

    • Interface Type

      BNC

    • Weight

      523g

    • Overall dimension

      Control box: 109mm x 24.2mm x 57.8mm //Current clamp: 170mm x 30mm x 65mm

    • Delay time

      Probe host 41ns //BNC 5ns (line length 1 m)

    • Cable length

      Control box to BNC connector cable length: 0.9m// Cable length from control box to current clamp: 1.4m

    $3,193.00
  • ETA56150U  Current probe
    • Bandwidth

      DC-15MHz

    • Current

      DC/AC RMS 150A

    • Rise time

      ≤24ns

    • Range sensitivity

      0.1V/A 0.01V/A

    • Typical DC Accuracy

      士1%+20mA@0.1V/A 士1%+200mA@0.01V/A

    • Maximum operating voltage

      600V CATII 300V CATIII

    • Zero adjustment mode

      Automatic

    • Power supply modenction

      12V/2A power supply

    • Jaw diameter

      Φ19mm

    • Interface Type

      BNC

    • Weight

      523g

    • Overall dimension

      Control box: 109mm x 24.2mm x 57.8mm //Current clamp: 170mm x 30mm x 65mm

    • Delay time

      Probe host 37ns //BNC 5ns (line length 1 m)

    • Cable length

      Control box to BNC connector cable length: 0.9m// Cable length from control box to current clamp: 1.4m

    $2,121.00
  • ETA5540C  Current probe
    • Bandwidth

      DC-100MHz

    • Current

      DC/AC peak 40A

    • Rise time

      ≤3.5ns

    • Range sensitivity

      50mV/A

    • Typical DC Accuracy

      士2%rdg

    • Maximum operating voltage

      CATI 400V

    • Zero adjustment mode

      Automatic

    • Power supply modenction

      5V/2A power supply

    • Jaw diameter

      Φ4.5mm

    • Interface Type

      BNC

    • Weight

      200g

    • Overall dimension

      230mmx45.5mmx24.5mm

    • Maximum pulse current

      50A(TP≤10uS)

    • Noise

      ≤1mVrms

    • Linearity

      ±1%

    • Delay time

      20ns

    • Cable length

      130cm

    $1,491.00
  • ETA56300U  Current probe
    • Bandwidth

      DC-6MHz

    • Current

      DC/AC RMS 300A

    • Rise time

      ≤58ns

    • Range sensitivity

      0.1V/A 0.01V/A

    • Typical DC Accuracy

      士1%+20mA@0.1V/A 士1%+200mA@0.01V/A

    • Maximum operating voltage

      600V CATII 300V CATIII

    • Zero adjustment mode

      Automatic

    • Power supply modenction

      12V/2A power supply

    • Jaw diameter

      Φ19mm

    • Interface Type

      BNC

    • Weight

      523g

    • Overall dimension

      Control box: 109mm x 24.2mm x 57.8mm //Current clamp: 170mm x 30mm x 65mm

    • Delay time

      Probe host 41ns //BNC 5ns (line length 1 m)

    • Cable length

      Control box to BNC connector cable length: 0.9m// Cable length from control box to current clamp: 1.4m

    $2,764.00
  • ETA56500A  Current probe
    • Bandwidth

      DC-5MHz

    • Current

      DC/AC RMS 500A

    • Rise time

      ≤70ns

    • Range sensitivity

      0.1V/A 0.01V/A

    • Typical DC Accuracy

      士1%+10mA@0.1V/A 士1%+100mA@0.01V/A

    • Maximum operating voltage

      600V CATII 300V CATIII

    • Zero adjustment mode

      Automatic

    • Power supply modenction

      12V/2A power supply

    • Jaw diameter

      Φ19mm

    • Interface Type

      BNC

    • Weight

      523g

    • Overall dimension

      Control box: 109mm x 24.2mm x 57.8mm //Current clamp: 170mm x 30mm x 65mm

    • Delay time

      Probe host 42ns //BNC 5ns (line length 1 m)

    • Cable length

      Control box to BNC connector cable length: 0.9m// Cable length from control box to current clamp: 1.4m

    $3,836.00